ITT / STC Side-View Nixie Tubes

GN6

Standard Telephones (STC) side view nixie with 14 mm digits 0 - 9. No decimal point is provided.

Cathode currents should be in the range 1.25 mA (for full coverage) to 2.5 mA (average). The normal maintaining voltage is 115 V.
Pin out (pins are numbered clockwise from the gap looking at the tube from below):

Pin

1

2

3

4

5

6

7

8

9

10

11

Electrode

a

k0

k1

k2

k3

k4

k5

k6

k7

k8

k9


GS6

Standard Telephones (STC) side view nixie with 10 mm. symbols +, - and ~.
Recommended cathode current is 2 mA. The normal maintaining voltage is 140 V.
On the sample shown here there are only 4 pins, the remaining 3 pins do not protude from the base, although they are present internally. The pin out (pins are numbered clockwise from the gap, looking at the tube from below) is :-

Pin

1

2

3

4

5

6

7

Electrode

a

-

k-

-

k~

-

k+


© Andy Cowley 2006 - 2008